Double Channel Syringe Pump

৳ 80,000.00

Product: Double Channel Syringe Pump
Brand: Leien Medical
Model: Linz-8B
Origin: China

Technical Specifications:
– Dimensions(mm): 271(L)×167(W)×287(H)
– Weight: 3.6kg
– Power supply: AC 100V~AC 242V、50/60HZ(±1 HZ)
– Built-in batteries: DC 12V 2800mAh
– Battery Model: Rechargeable
– Battery Continuous Use Time:At least 6hrs for single channel(Fully
charged new battery, under 5ml/h running)
– Power consumption:≤42 VA
– Infusion Flow Selection: 0.1ml/h~1600ml/h, original value is 0.1ml/h
– Bolus rate:
Syringe 50ml:1600ml/h
Syringe 30ml:900 ml/h
Syringe 20ml:600 ml/h
Syringe 10ml:400 ml/h
– Infusion Range:0.1ml~9999.9ml, original value is 0.1ml
– Flow Rate Precision: ±3%
– Occlusion Pressure: High:110kPa±20kPa (825mmHg±150 mmHg)
Middle:80kPa±30kPa (600mmHg±225mmHg)
Low:60kPa±20kPa (450mmHg±150 mmHg)
– The biggest output pressure: < 975mmHg(130kPa)
– Waterproof Level: IPX4
– Electric Shock Protection: Class I, Type CF
– Alarm: occlusion, nearly finish, finish, standby (no operation) low battery, battery exhausted etc.
Function: transfusion amount display, flow rate display, infused volume display
Special Function
– KVO (Keep Vein Open):After finish setting infusion amount, for prevent to form thrombus, keep to infusion at the lowest rate 0.1ml/h.
– Power Switching Function:When AC power is disconnected, automatically switch into battery power supply and give indication. When the AC power is connected, automatically switch into AC power working.
– Repeat Alarm Function: If the alarm real reason is not be resolved within 2 minutes after press “SILENCE” button, it will give alarm again to remind to resolve the problem.
– Data Memory Function: Able to save the latest setting alarm volume level, brand, occlusion pressure level for use next time. Able to save for five years.
– Battery Protection Alarm: For protect battery and safety infusion, the battery power will be displayed as different levels in sound and light from nearly finish to exhausted.
– Move alarm: When try to move or take the syringe away, it will give alarm.

Add to Wishlist
Add to Wishlist

Description

Product: Double Channel Syringe Pump
Brand: Leien Medical
Model: Linz-8B
Origin: China

Technical Specifications:
– Dimensions(mm): 271(L)×167(W)×287(H)
– Weight: 3.6kg
– Power supply: AC 100V~AC 242V、50/60HZ(±1 HZ)
– Built-in batteries: DC 12V 2800mAh
– Battery Model: Rechargeable
– Battery Continuous Use Time:At least 6hrs for single channel(Fully
charged new battery, under 5ml/h running)
– Power consumption:≤42 VA
– Infusion Flow Selection: 0.1ml/h~1600ml/h, original value is 0.1ml/h
– Bolus rate:
Syringe 50ml:1600ml/h
Syringe 30ml:900 ml/h
Syringe 20ml:600 ml/h
Syringe 10ml:400 ml/h
– Infusion Range:0.1ml~9999.9ml, original value is 0.1ml
– Flow Rate Precision: ±3%
– Occlusion Pressure: High:110kPa±20kPa (825mmHg±150 mmHg)
Middle:80kPa±30kPa (600mmHg±225mmHg)
Low:60kPa±20kPa (450mmHg±150 mmHg)
– The biggest output pressure: < 975mmHg(130kPa)
– Waterproof Level: IPX4
– Electric Shock Protection: Class I, Type CF
– Alarm: occlusion, nearly finish, finish, standby (no operation) low battery, battery exhausted etc.
Function: transfusion amount display, flow rate display, infused volume display
Special Function
– KVO (Keep Vein Open):After finish setting infusion amount, for prevent to form thrombus, keep to infusion at the lowest rate 0.1ml/h.
– Power Switching Function:When AC power is disconnected, automatically switch into battery power supply and give indication. When the AC power is connected, automatically switch into AC power working.
– Repeat Alarm Function: If the alarm real reason is not be resolved within 2 minutes after press “SILENCE” button, it will give alarm again to remind to resolve the problem.
– Data Memory Function: Able to save the latest setting alarm volume level, brand, occlusion pressure level for use next time. Able to save for five years.
– Battery Protection Alarm: For protect battery and safety infusion, the battery power will be displayed as different levels in sound and light from nearly finish to exhausted.
– Move alarm: When try to move or take the syringe away, it will give alarm.